{"id":109,"date":"2015-12-18T14:14:44","date_gmt":"2015-12-18T08:44:44","guid":{"rendered":"https:\/\/tazurbaa.com\/index.php\/juice-heaters\/"},"modified":"2022-06-20T16:46:21","modified_gmt":"2022-06-20T11:16:21","slug":"juice-heaters","status":"publish","type":"page","link":"https:\/\/niftyonline.co.in\/turnkey-sugar-factory\/juice-heaters\/","title":{"rendered":"Juice Heaters"},"content":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1655719790778{border-bottom-width: 1px !important;border-bottom-color: #eaeaea !important;border-bottom-style: dashed !important;}&#8221;][vc_column width=&#8221;2\/3&#8243;][vc_custom_heading text=&#8221;Direct Contact Heaters (DCH)&#8221; font_container=&#8221;tag:h3|text_align:left&#8221; use_theme_fonts=&#8221;yes&#8221;][vc_empty_space height=&#8221;20px&#8221;][vc_column_text]Direct Contact Heater is an alternative heat exchanger to plate and tubular heaters. contact heaters<\/p>\n<p>DCH will work with counter current heat exchange principle. DCH has high heat transfer co-efficient. In the DCH latent heat and part of sensible heat will be utilized for heating duty.<br \/>\nDCH will work with an approach temperature of 0-2\u00b0C, whereas tubular heaters and plate heat exchangers will work with 5-7\u00b0 C approach temperature.<\/p>\n<h4>Advantages Of DCH:<\/h4>\n<div class=\"bullets\">\n<ul>\n<li>Counter current operation and high heat transfer co-efficient.<\/li>\n<li>Can be run with bled vapours and saving of exhaust steam.<\/li>\n<li>Effective utilization of the latent heat and part of the sensible heat.<\/li>\n<li>Suitable for heating with low pressure and temperature vapours.<\/li>\n<li>No condensate extraction system is required.<\/li>\n<li>Low head juice pumps and less power consumption.<\/li>\n<li>0-2\u00b0 C approach temperature.<\/li>\n<li>Suitable for complete automation.<\/li>\n<li>Can be operated at pressure and vacuum.<\/li>\n<\/ul>\n<\/div>\n<p>[\/vc_column_text][vc_empty_space][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;1291&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; style=&#8221;vc_box_shadow_border&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1655723661607{border-bottom-width: 1px !important;border-bottom-color: #eaeaea !important;border-bottom-style: dashed !important;}&#8221;][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;1295&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; style=&#8221;vc_box_shadow_border&#8221;][vc_empty_space height=&#8221;50px&#8221;][\/vc_column][vc_column width=&#8221;2\/3&#8243;][vc_empty_space][vc_custom_heading text=&#8221;Duplex Heat Exchangers (DHE)&#8221; font_container=&#8221;tag:h3|text_align:left&#8221; use_theme_fonts=&#8221;yes&#8221;][vc_empty_space height=&#8221;20px&#8221;][vc_column_text]Duplex Heat Exchangers are tubular heat exchangers to heat or cool the liquids. DHE are an assembly of multiple small heat exchangers having single or double pass. DHE shall work with high heat transfer co\u00acefficient. DHE are suitable for sugar industry as well as chemical and paper industry.<\/p>\n<h4>Advantages of DHE:<\/h4>\n<div class=\"bullets\">\n<ul>\n<li>Liquid to liquid Counter current heat exchange.<\/li>\n<li>High heat transfer co-efficient.<\/li>\n<li>Can be utilized for waste heat recovery, hence steam saving of 1% on cane.<\/li>\n<li>Suitable for heating and cooling of liquids and wide range of applications.<\/li>\n<li>Easy to install and requires less space.<\/li>\n<li>Easy cleaning of tube and less maintenance.<\/li>\n<li>Lesser cost of installation.<\/li>\n<\/ul>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;50px&#8221;][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1655719790778{border-bottom-width: 1px !important;border-bottom-color: #eaeaea !important;border-bottom-style: dashed !important;}&#8221;][vc_column width=&#8221;2\/3&#8243;][vc_custom_heading text=&#8221;Tubular Type Juice Heater&#8221; font_container=&#8221;tag:h3|text_align:left&#8221; use_theme_fonts=&#8221;yes&#8221;][vc_empty_space height=&#8221;20px&#8221;][vc_column_text]Juice Heaters consist of an assembly of tubes and shell. Juice circulates through the tubes and the vapor passes in the shell.<\/p>\n<h4>Shrijee offers the following types of tubular juice heaters:<\/h4>\n<div class=\"bullets\">\n<ul>\n<li>Vertical Tubular Juice Heater<\/li>\n<li>Vapor Line Tubular Juice Heater<\/li>\n<li>Dynamic Tubular Juice Heater<\/li>\n<\/ul>\n<\/div>\n<p>Shrijee\u2019s juice heater manufacturing range is 100 M<sup>2<\/sup>\u00a0HSA to 500 M<sup>2<\/sup>\u00a0HAS. The material for the shell is Mild Steel and for tubes is SS 304. Operating Temperature is 30<sup>0<\/sup>C to 105<sup>0<\/sup>C. The juice velocity in the tubes is 1.5 Mtr\/Sec to 2.0 Mtr\/Sec.<\/p>\n<h4>Important features of Shrijee Juice Heater:<\/h4>\n<div class=\"bullets\">\n<ul>\n<li>Multi-circulation of juice<\/li>\n<li>Efficient distribution of vapor\/steam<\/li>\n<li>Easy to open cover<\/li>\n<li>Leak proof passes for higher efficiency<\/li>\n<li>Positive removal of condensate<\/li>\n<li>Proper venting<\/li>\n<\/ul>\n<\/div>\n<p>[\/vc_column_text][vc_empty_space][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_empty_space height=&#8221;20px&#8221;][vc_single_image image=&#8221;1301&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; style=&#8221;vc_box_shadow_border&#8221;][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1655719790778{border-bottom-width: 1px !important;border-bottom-color: #eaeaea !important;border-bottom-style: dashed !important;}&#8221;][vc_column width=&#8221;2\/3&#8243;][vc_custom_heading text=&#8221;Direct Contact Heaters (DCH)&#8221; font_container=&#8221;tag:h3|text_align:left&#8221; use_theme_fonts=&#8221;yes&#8221;][vc_empty_space height=&#8221;20px&#8221;][vc_column_text]Direct Contact Heater is an alternative heat exchanger to plate and tubular heaters. contact heaters DCH will work with counter current heat exchange principle. DCH has high heat transfer co-efficient. In the DCH latent heat and part of sensible heat will be utilized for heating duty. DCH will work with an approach temperature of 0-2\u00b0C, whereas tubular heaters and plate [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":1294,"parent":0,"menu_order":4,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-109","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/niftyonline.co.in\/turnkey-sugar-factory\/wp-json\/wp\/v2\/pages\/109","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/niftyonline.co.in\/turnkey-sugar-factory\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/niftyonline.co.in\/turnkey-sugar-factory\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/niftyonline.co.in\/turnkey-sugar-factory\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/niftyonline.co.in\/turnkey-sugar-factory\/wp-json\/wp\/v2\/comments?post=109"}],"version-history":[{"count":14,"href":"https:\/\/niftyonline.co.in\/turnkey-sugar-factory\/wp-json\/wp\/v2\/pages\/109\/revisions"}],"predecessor-version":[{"id":1306,"href":"https:\/\/niftyonline.co.in\/turnkey-sugar-factory\/wp-json\/wp\/v2\/pages\/109\/revisions\/1306"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/niftyonline.co.in\/turnkey-sugar-factory\/wp-json\/wp\/v2\/media\/1294"}],"wp:attachment":[{"href":"https:\/\/niftyonline.co.in\/turnkey-sugar-factory\/wp-json\/wp\/v2\/media?parent=109"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}